Off-grid pumping

Solar Submersible Pump for 3,000 GPD at 300 ft TDH

Compare flow and array power for a high-head solar well supplying 3,000 gal/day through a six-hour pump window.

Inputs

PV array nameplate power1,565.8 W

Water and sun

gal/day
ft
h/dayDaily solar energy expressed as equivalent full-sun hours.
h/dayUsed to size pump flow and instantaneous power.
%
daysDays of demand to compare for cistern and battery storage.
PV losses and well yield
°FCell temperature during operation.
%/°FPositive magnitude of the module data-sheet coefficient.
%
%
gpmEnter 0 if you do not have a yield test.
Battery assumptions
%
%
%
V

Results

Updates as you edit
PV array nameplate power1,565.8 W

The pumping window requires more flow than the tested well yield.

PV sizing limits
PV sizing limitsThe direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.Daily energy1,565.8 WDirect power1,435.3 WSelected array1,565.8 W

The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.

Required pump flow
8.33 gpm
Pump electrical demand
1,045.8 W
Daily hydraulic energy
2.824 kWh/day
Daily pump electricity
6.275 kWh/day
PV output factor
72.9 %
Energy-limited array
1,565.8 W
Direct-pumping power floor
1,435.3 W
Cistern buffer equivalent
6,000 gal
Nominal battery equivalent
17.05 kWh
Battery capacity at bank voltage
355.2 Ah

Worked calculation

  1. Set the pump duty

    Q = daily volume / hours actually pumping

    3,000 gal/day in 6 h/day gives 8.33 gpm at 300 ft of TDH.

  2. Find the electrical energy at the pump

    Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.

    The water needs 2.824 kWh/day. At 45 % efficiency, the pump needs 6.275 kWh/day.

  3. Derate the PV modules

    PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)

    The temperature factor is 88 % and the combined output factor is 72.9 %.

  4. Check daily energy and instantaneous power

    Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)

    Daily energy gives 1,565.8 W. Direct pumping needs at least 1,435.3 W in the design-sun condition. The chosen mode yields 1,565.8 W.

  5. Allow for storage autonomy

    Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).

    2 days gives 6,000 gal of cistern storage or 17.05 kWh of nominal battery capacity.

What this example shows

The modeled flow exceeds the entered 7 gpm well yield. Adjust the pumping schedule or daily target and confirm the sustained yield with a well test.

Frequently asked questions

Will a bigger PV array fix a low-yield well at 3,000 GPD?

More PV can help supply power, but the well must still sustain the pump’s flow for the entered operating time.

What pump data matters for a 300 ft solar application?

Check delivery at the full TDH and planned flow, then check motor, controller and dry-run protection requirements.