Solar Well Pump for 1,000 GPD of Livestock Water
Size a solar livestock well delivering 1,000 gal/day against 150 ft TDH with five peak sun hours and two days of water storage.
Inputs
Results
Updates as you editDirect pumping uses the larger of the daily energy and instantaneous power estimates.
The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.
- Required pump flow
- 3.33 gpm
- Pump electrical demand
- 224.1 W
- Daily hydraulic energy
- 0.471 kWh/day
- Daily pump electricity
- 1.121 kWh/day
- PV output factor
- 72.9 %
- Energy-limited array
- 307.6 W
- Direct-pumping power floor
- 307.6 W
- Cistern buffer equivalent
- 2,000 gal
- Nominal battery equivalent
- 3.04 kWh
- Battery capacity at bank voltage
- 63.4 Ah
Inputs
- Daily water target
- 1,000 gal/day
- Total dynamic head
- 150 ft
- Peak sun hours
- 5 h/day
- Actual pumping window
- 5 h/day
- Wire-to-water efficiency
- 42 %
- Operating mode
- Direct pump + cistern
- Storage autonomy
- 2 days
- Design PV cell temperature
- 131 °F
- Power loss per degree
- 0.222 %/°F
- Soiling loss
- 8 %
- Wiring and mismatch loss
- 10 %
- Tested well yield
- 5 gpm
- Battery round-trip efficiency
- 85 %
- Discharge-path efficiency
- 92 %
- Usable depth of discharge
- 80 %
- Battery bank voltage
- 48 V
Worked calculation
Set the pump duty
Q = daily volume / hours actually pumping
1,000 gal/day in 5 h/day gives 3.33 gpm at 150 ft of TDH.
Find the electrical energy at the pump
Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.
The water needs 0.471 kWh/day. At 42 % efficiency, the pump needs 1.121 kWh/day.
Derate the PV modules
PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)
The temperature factor is 88 % and the combined output factor is 72.9 %.
Check daily energy and instantaneous power
Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)
Daily energy gives 307.6 W. Direct pumping needs at least 307.6 W in the design-sun condition. The chosen mode yields 307.6 W.
Allow for storage autonomy
Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).
2 days gives 2,000 gal of cistern storage or 3.04 kWh of nominal battery capacity.
What this example shows
The pump must deliver about 3.33 gpm. The two-day reserve is 2,000 usable gallons. Compare the array result with the pump-controller vendor’s array and voltage limits.
Frequently asked questions
How much usable livestock water storage gives two days at 1,000 GPD?
Two days at 1,000 gallons per day requires 2,000 gallons of usable storage. Space above the usable outlet level is separate.
How can a livestock trough fill after sunset with direct solar pumping?
Use a cistern that stores daytime production and feeds the trough later through gravity or a separately powered pressure system.