Off-grid pumping

Solar Well Pump for 1,000 GPD of Livestock Water

Size a solar livestock well delivering 1,000 gal/day against 150 ft TDH with five peak sun hours and two days of water storage.

Inputs

PV array nameplate power307.6 W

Water and sun

gal/day
ft
h/dayDaily solar energy expressed as equivalent full-sun hours.
h/dayUsed to size pump flow and instantaneous power.
%
daysDays of demand to compare for cistern and battery storage.
PV losses and well yield
°FCell temperature during operation.
%/°FPositive magnitude of the module data-sheet coefficient.
%
%
gpmEnter 0 if you do not have a yield test.
Battery assumptions
%
%
%
V

Results

Updates as you edit
PV array nameplate power307.6 W

Direct pumping uses the larger of the daily energy and instantaneous power estimates.

PV sizing limits
PV sizing limitsThe direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.Daily energy307.6 WDirect power307.6 WSelected array307.6 W

The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.

Required pump flow
3.33 gpm
Pump electrical demand
224.1 W
Daily hydraulic energy
0.471 kWh/day
Daily pump electricity
1.121 kWh/day
PV output factor
72.9 %
Energy-limited array
307.6 W
Direct-pumping power floor
307.6 W
Cistern buffer equivalent
2,000 gal
Nominal battery equivalent
3.04 kWh
Battery capacity at bank voltage
63.4 Ah

Worked calculation

  1. Set the pump duty

    Q = daily volume / hours actually pumping

    1,000 gal/day in 5 h/day gives 3.33 gpm at 150 ft of TDH.

  2. Find the electrical energy at the pump

    Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.

    The water needs 0.471 kWh/day. At 42 % efficiency, the pump needs 1.121 kWh/day.

  3. Derate the PV modules

    PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)

    The temperature factor is 88 % and the combined output factor is 72.9 %.

  4. Check daily energy and instantaneous power

    Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)

    Daily energy gives 307.6 W. Direct pumping needs at least 307.6 W in the design-sun condition. The chosen mode yields 307.6 W.

  5. Allow for storage autonomy

    Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).

    2 days gives 2,000 gal of cistern storage or 3.04 kWh of nominal battery capacity.

What this example shows

The pump must deliver about 3.33 gpm. The two-day reserve is 2,000 usable gallons. Compare the array result with the pump-controller vendor’s array and voltage limits.

Frequently asked questions

How much usable livestock water storage gives two days at 1,000 GPD?

Two days at 1,000 gallons per day requires 2,000 gallons of usable storage. Space above the usable outlet level is separate.

How can a livestock trough fill after sunset with direct solar pumping?

Use a cistern that stores daytime production and feeds the trough later through gravity or a separately powered pressure system.