Piping hydraulics

1-Inch vs 1¼-Inch PVC Friction Loss at 15 GPM

Compare 100 ft of two Schedule 40 PVC sizes at 15 gpm using actual bores, velocity and both loss methods.

Inputs

Darcy total head loss11.84 ft

Pipe and flow

gpm
ftMeasure along the pipe, including vertical runs.
°F
Same as primary carries through its C and roughness settings.
Fittings and pipe overrides
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.

Water hammer inputs

ft/sUse a pipe-specific wave speed where available.
s
%
psig

Results

Updates as you edit
Darcy total head loss11.84 ft

Turbulent flow. Velocity exceeds the 5 ft/s screening threshold for velocity-related wear and surge. Closure falls in the sudden-closure screening range.

Head loss versus flow
Head loss versus flowEach curve includes the entered fitting K. The marker identifies the primary Darcy–Weisbach duty.04.5913.51822.506.7813.5520.3327.11Flow (gpm)Total loss (ft)Design flow · 11.84 ft
  • Darcy–Weisbach
  • Hazen–Williams
  • Comparison · Darcy

Each curve includes the entered fitting K. The marker identifies the primary Darcy–Weisbach duty.

Hazen–Williams total head loss
11.63 ft
Darcy pressure drop
5.12 psi
Water velocity
5.57 ft/s
Reynolds number
45,064
Darcy friction factor
0.02147
Fitting head loss
0 ft
Pipe inside diameter
1.049 in
Comparison Darcy loss
3.19 ft
Comparison Hazen–Williams loss
3.06 ft
Comparison velocity
3.22 ft/s
Comparison inside diameter
1.38 in
Sudden-closure pressure rise
82.39 psi
Initial pressure + sudden-closure rise
127.39 psig
Wave round-trip time
0.1818 s

Worked calculation

  1. Find velocity and flow regime

    v = Q/A. Re = ρvD/μ.

    15 gpm in a 1.049 in bore gives 5.57 ft/s. Re = 45,064 (turbulent).

  2. Calculate straight-pipe loss two ways

    Darcy: f(L/D)v²/(2g). Hazen–Williams: 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI.

    Across 100 ft, Darcy gives 11.84 ft and Hazen–Williams gives 11.63 ft.

  3. Add fitting losses

    Hₖ = ΣK v²/(2g)

    Total K is 0 and adds 0 ft. Total Darcy loss is 11.84 ft. The comparison bore gives 3.19 ft at the same flow.

  4. Screen surge from a sudden change in flow

    Δp = ρaΔv. Wave round-trip time = 2L/a.

    The arrested velocity is 5.57 ft/s and the wave speed is 1,100 ft/s. The pressure rise estimate is 82.39 psi with a round-trip time of 0.1818 s.

What this example shows

The 1-inch bore carries water above the 5 ft/s screening threshold. The larger bore reduces velocity and head loss. Increase the length to see how straight-pipe loss changes.

Frequently asked questions

Why do 1.049 and 1.380 inches appear for these PVC sizes?

They are the representative inside bores of the nominal 1-inch and 1¼-inch Schedule 40 sizes.

At 15 gpm does a longer straight PVC line increase velocity?

Velocity is set by flow and the inside area. Doubling the length doubles the straight-pipe head loss at constant flow.