Booster Pump Power Increase from 25 Hz to 40 Hz
Compare flow, head and electrical load when raising a booster’s reference operating speed from 25 Hz to 40 Hz.
Inputs
Results
Updates as you editHigher frequency raises shaft load. Check the motor and pump speed limits.
- Flow ∝ speed
- Head ∝ speed²
- Power ∝ speed³
The marker shows target-speed power as a share of base power.
- Hydraulic water power
- 0.13 hp
- Brake power at pump shaft
- 0.26 hp
- Motor electrical input equivalent
- 0.32 hp
- Wire-to-water efficiency
- 40.9 %
- Target-speed flow
- 22.4 gpm
- Target-speed head
- 97.28 ft
- Target-speed electrical input
- 1 kW
- Base annual energy
- 379.9 kWh
- Target annual energy
- 1,556 kWh
- Base annual electricity cost
- 53.18 USD
- Target annual electricity cost
- 217.84 USD
- Annual cost difference
- -164.66 USD
Inputs
- Design flow
- 14 gpm
- Total dynamic head
- 38 ft
- Pump efficiency
- 52 %
- Motor efficiency
- 82 %
- Base frequency
- 25 Hz
- Target frequency
- 40 Hz
- Run time
- 5 h/day
- Operating days per year
- 310 days
- Energy tariff
- 0.14 USD/kWh
- Liquid specific gravity
- 1
- Drive efficiency
- 96 %
Worked calculation
Calculate useful water power
Pwater = ρgQH
14 gpm at 38 ft and specific gravity 1 requires 0.13 hp of hydraulic work.
Allow for pump, motor and drive losses
Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.
The shaft needs 0.26 hp. Motor input is 0.32 hp and electrical input before the drive is 0.25 kW.
Scale to the target frequency
r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.
40 Hz ÷ 25 Hz gives a speed ratio of 1.6. Target input is 1 kW.
Estimate annual energy and cost
Annual kWh = input kW × annual hours. Cost = kWh × tariff.
5 h/day × 310 days gives 1,550 h per year. The two speeds use 379.9 kWh and 1,556 kWh.
What this example shows
The speed ratio is 1.6. The cubic projection raises input power by a factor of 4.096 at the corresponding duty. Check motor loading and pressure at the higher speed.
Frequently asked questions
Why is the reported annual cost difference negative for the higher speed?
The displayed difference is base cost minus target cost. A negative value means the target speed costs more.
Which speed belongs in the base frequency field for this booster?
Use the frequency at which the entered flow and head are known, here 25 Hz.