Power and energy

Booster Pump Power Increase from 25 Hz to 40 Hz

Compare flow, head and electrical load when raising a booster’s reference operating speed from 25 Hz to 40 Hz.

Inputs

Electrical input at base speed0.25 kW

Duty and efficiency

gpm
ft
%
%
Hz
Hz
h/day
days
Electricity and fluid
USD/kWh
Use 1.00 for water in this estimate.
%Enter 100% without a drive.

Results

Updates as you edit
Electrical input at base speed0.25 kW

Higher frequency raises shaft load. Check the motor and pump speed limits.

Affinity laws at variable speed
Affinity laws at variable speedThe marker shows target-speed power as a share of base power.03264961281600112.64225.28337.92450.56Base speed (%)Base duty (%)Target power · 409.6 %
  • Flow ∝ speed
  • Head ∝ speed²
  • Power ∝ speed³

The marker shows target-speed power as a share of base power.

Hydraulic water power
0.13 hp
Brake power at pump shaft
0.26 hp
Motor electrical input equivalent
0.32 hp
Wire-to-water efficiency
40.9 %
Target-speed flow
22.4 gpm
Target-speed head
97.28 ft
Target-speed electrical input
1 kW
Base annual energy
379.9 kWh
Target annual energy
1,556 kWh
Base annual electricity cost
53.18 USD
Target annual electricity cost
217.84 USD
Annual cost difference
-164.66 USD

Worked calculation

  1. Calculate useful water power

    Pwater = ρgQH

    14 gpm at 38 ft and specific gravity 1 requires 0.13 hp of hydraulic work.

  2. Allow for pump, motor and drive losses

    Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.

    The shaft needs 0.26 hp. Motor input is 0.32 hp and electrical input before the drive is 0.25 kW.

  3. Scale to the target frequency

    r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.

    40 Hz ÷ 25 Hz gives a speed ratio of 1.6. Target input is 1 kW.

  4. Estimate annual energy and cost

    Annual kWh = input kW × annual hours. Cost = kWh × tariff.

    5 h/day × 310 days gives 1,550 h per year. The two speeds use 379.9 kWh and 1,556 kWh.

What this example shows

The speed ratio is 1.6. The cubic projection raises input power by a factor of 4.096 at the corresponding duty. Check motor loading and pressure at the higher speed.

Frequently asked questions

Why is the reported annual cost difference negative for the higher speed?

The displayed difference is base cost minus target cost. A negative value means the target speed costs more.

Which speed belongs in the base frequency field for this booster?

Use the frequency at which the entered flow and head are known, here 25 Hz.