Power and energy

Well Pump kWh Cost at $0.28 per kWh

Apply a high electricity tariff to an 18 gpm well pump at 180 ft of head running 2.5 hours per day.

Inputs

Electrical input at base speed1.33 kW

Duty and efficiency

gpm
ft
%
%
Hz
Hz
h/day
days
Electricity and fluid
USD/kWh
Use 1.00 for water in this estimate.
%Enter 100% without a drive.

Results

Updates as you edit
Electrical input at base speed1.33 kW

Affinity estimates assume comparable pump efficiency and the same run hours.

Affinity laws at variable speed
Affinity laws at variable speedThe marker shows target-speed power as a share of base power.020406080100027.55582.5110Base speed (%)Base duty (%)Target power · 100 %
  • Flow ∝ speed
  • Head ∝ speed²
  • Power ∝ speed³

The marker shows target-speed power as a share of base power.

Hydraulic water power
0.82 hp
Brake power at pump shaft
1.52 hp
Motor electrical input equivalent
1.79 hp
Wire-to-water efficiency
45.9 %
Target-speed flow
18 gpm
Target-speed head
180 ft
Target-speed electrical input
1.33 kW
Base annual energy
1,214.7 kWh
Target annual energy
1,214.7 kWh
Base annual electricity cost
340.11 USD
Target annual electricity cost
340.11 USD
Annual cost difference
0 USD

Worked calculation

  1. Calculate useful water power

    Pwater = ρgQH

    18 gpm at 180 ft and specific gravity 1 requires 0.82 hp of hydraulic work.

  2. Allow for pump, motor and drive losses

    Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.

    The shaft needs 1.52 hp. Motor input is 1.79 hp and electrical input before the drive is 1.33 kW.

  3. Scale to the target frequency

    r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.

    60 Hz ÷ 60 Hz gives a speed ratio of 1. Target input is 1.33 kW.

  4. Estimate annual energy and cost

    Annual kWh = input kW × annual hours. Cost = kWh × tariff.

    2.5 h/day × 365 days gives 912.5 h per year. The two speeds use 1,214.7 kWh and 1,214.7 kWh.

What this example shows

Use a bill’s marginal energy charge if the goal is to estimate how a change in runtime affects cost. The annual kWh stays the same as you edit the tariff.

Frequently asked questions

What happens to annual kWh when I enter a different electricity tariff?

The tariff changes cost only. The estimated energy depends on duty, efficiency and run hours.

Can this well example include a monthly service charge?

The calculator multiplies energy by a single tariff. Add fixed monthly charges separately if they belong in your comparison.