Well Pump kWh Cost at $0.28 per kWh
Apply a high electricity tariff to an 18 gpm well pump at 180 ft of head running 2.5 hours per day.
Inputs
Results
Updates as you editAffinity estimates assume comparable pump efficiency and the same run hours.
- Flow ∝ speed
- Head ∝ speed²
- Power ∝ speed³
The marker shows target-speed power as a share of base power.
- Hydraulic water power
- 0.82 hp
- Brake power at pump shaft
- 1.52 hp
- Motor electrical input equivalent
- 1.79 hp
- Wire-to-water efficiency
- 45.9 %
- Target-speed flow
- 18 gpm
- Target-speed head
- 180 ft
- Target-speed electrical input
- 1.33 kW
- Base annual energy
- 1,214.7 kWh
- Target annual energy
- 1,214.7 kWh
- Base annual electricity cost
- 340.11 USD
- Target annual electricity cost
- 340.11 USD
- Annual cost difference
- 0 USD
Inputs
- Design flow
- 18 gpm
- Total dynamic head
- 180 ft
- Pump efficiency
- 54 %
- Motor efficiency
- 85 %
- Base frequency
- 60 Hz
- Target frequency
- 60 Hz
- Run time
- 2.5 h/day
- Operating days per year
- 365 days
- Energy tariff
- 0.28 USD/kWh
- Liquid specific gravity
- 1
- Drive efficiency
- 100 %
Worked calculation
Calculate useful water power
Pwater = ρgQH
18 gpm at 180 ft and specific gravity 1 requires 0.82 hp of hydraulic work.
Allow for pump, motor and drive losses
Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.
The shaft needs 1.52 hp. Motor input is 1.79 hp and electrical input before the drive is 1.33 kW.
Scale to the target frequency
r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.
60 Hz ÷ 60 Hz gives a speed ratio of 1. Target input is 1.33 kW.
Estimate annual energy and cost
Annual kWh = input kW × annual hours. Cost = kWh × tariff.
2.5 h/day × 365 days gives 912.5 h per year. The two speeds use 1,214.7 kWh and 1,214.7 kWh.
What this example shows
Use a bill’s marginal energy charge if the goal is to estimate how a change in runtime affects cost. The annual kWh stays the same as you edit the tariff.
Frequently asked questions
What happens to annual kWh when I enter a different electricity tariff?
The tariff changes cost only. The estimated energy depends on duty, efficiency and run hours.
Can this well example include a monthly service charge?
The calculator multiplies energy by a single tariff. Add fixed monthly charges separately if they belong in your comparison.