Brine Pump Horsepower at Specific Gravity 1.12
Compare hydraulic and shaft horsepower for 80 gpm of brine at 95 ft of head and specific gravity 1.12.
Inputs
Results
Updates as you editAffinity estimates assume comparable pump efficiency and the same run hours.
- Flow ∝ speed
- Head ∝ speed²
- Power ∝ speed³
The marker shows target-speed power as a share of base power.
- Hydraulic water power
- 2.15 hp
- Brake power at pump shaft
- 3.47 hp
- Motor electrical input equivalent
- 3.86 hp
- Wire-to-water efficiency
- 54.7 %
- Target-speed flow
- 72 gpm
- Target-speed head
- 76.95 ft
- Target-speed electrical input
- 2.14 kW
- Base annual energy
- 9,863 kWh
- Target annual energy
- 7,190.1 kWh
- Base annual electricity cost
- 1,183.56 USD
- Target annual electricity cost
- 862.81 USD
- Annual cost difference
- 320.74 USD
Inputs
- Design flow
- 80 gpm
- Total dynamic head
- 95 ft
- Pump efficiency
- 62 %
- Motor efficiency
- 90 %
- Base frequency
- 60 Hz
- Target frequency
- 54 Hz
- Run time
- 12 h/day
- Operating days per year
- 280 days
- Energy tariff
- 0.12 USD/kWh
- Liquid specific gravity
- 1.12
- Drive efficiency
- 98 %
Worked calculation
Calculate useful water power
Pwater = ρgQH
80 gpm at 95 ft and specific gravity 1.12 requires 2.15 hp of hydraulic work.
Allow for pump, motor and drive losses
Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.
The shaft needs 3.47 hp. Motor input is 3.86 hp and electrical input before the drive is 2.94 kW.
Scale to the target frequency
r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.
54 Hz ÷ 60 Hz gives a speed ratio of 0.9. Target input is 2.14 kW.
Estimate annual energy and cost
Annual kWh = input kW × annual hours. Cost = kWh × tariff.
12 h/day × 280 days gives 3,360 h per year. The two speeds use 9,863 kWh and 7,190.1 kWh.
What this example shows
At a fixed flow, head and efficiency, power rises in proportion to density. Use process-fluid pump data when viscosity changes the duty or efficiency.
Frequently asked questions
Does 1.12 specific gravity add 12% to shaft power?
At the same flow, head and efficiency, yes. Pressure rise and hydraulic power scale with the density.
Can I apply this brine result to highly viscous fluid?
The arithmetic accepts density only. Use a viscosity-corrected pump curve and efficiency at the actual fluid temperature.