Power and energy

Annual Electricity Cost of a 5 HP Irrigation Pump

Estimate the electricity used by a 5 HP class irrigation pump delivering 125 gpm at 100 ft of head for a 155-day season.

Inputs

Electrical input at base speed4.06 kW

Duty and efficiency

gpm
ft
%
%
Hz
Hz
h/day
days
Electricity and fluid
USD/kWh
Use 1.00 for water in this estimate.
%Enter 100% without a drive.

Results

Updates as you edit
Electrical input at base speed4.06 kW

Affinity estimates assume comparable pump efficiency and the same run hours.

Affinity laws at variable speed
Affinity laws at variable speedThe marker shows target-speed power as a share of base power.020406080100027.55582.5110Base speed (%)Base duty (%)Target power · 100 %
  • Flow ∝ speed
  • Head ∝ speed²
  • Power ∝ speed³

The marker shows target-speed power as a share of base power.

Hydraulic water power
3.16 hp
Brake power at pump shaft
4.79 hp
Motor electrical input equivalent
5.44 hp
Wire-to-water efficiency
58.1 %
Target-speed flow
125 gpm
Target-speed head
100 ft
Target-speed electrical input
4.06 kW
Base annual energy
5,661.8 kWh
Target annual energy
5,661.8 kWh
Base annual electricity cost
1,075.74 USD
Target annual electricity cost
1,075.74 USD
Annual cost difference
0 USD

Worked calculation

  1. Calculate useful water power

    Pwater = ρgQH

    125 gpm at 100 ft and specific gravity 1 requires 3.16 hp of hydraulic work.

  2. Allow for pump, motor and drive losses

    Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.

    The shaft needs 4.79 hp. Motor input is 5.44 hp and electrical input before the drive is 4.06 kW.

  3. Scale to the target frequency

    r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.

    60 Hz ÷ 60 Hz gives a speed ratio of 1. Target input is 4.06 kW.

  4. Estimate annual energy and cost

    Annual kWh = input kW × annual hours. Cost = kWh × tariff.

    9 h/day × 155 days gives 1,395 h per year. The two speeds use 5,661.8 kWh and 5,661.8 kWh.

What this example shows

Seasonal kWh depends on measured input power and run hours. Adjust the tariff to your actual energy charge and add any demand charges separately.

Frequently asked questions

Does a 5 HP irrigation pump always draw 5 × 746 watts?

The motor rating describes shaft output at rated load. Duty point and motor efficiency determine the actual electrical input.

Where do I enter the irrigation season in this estimate?

Enter operating days per year and average hours per operating day. Entering 155 days gives the seasonal runtime used here.