Annual Electricity Cost of a 5 HP Irrigation Pump
Estimate the electricity used by a 5 HP class irrigation pump delivering 125 gpm at 100 ft of head for a 155-day season.
Inputs
Results
Updates as you editAffinity estimates assume comparable pump efficiency and the same run hours.
- Flow ∝ speed
- Head ∝ speed²
- Power ∝ speed³
The marker shows target-speed power as a share of base power.
- Hydraulic water power
- 3.16 hp
- Brake power at pump shaft
- 4.79 hp
- Motor electrical input equivalent
- 5.44 hp
- Wire-to-water efficiency
- 58.1 %
- Target-speed flow
- 125 gpm
- Target-speed head
- 100 ft
- Target-speed electrical input
- 4.06 kW
- Base annual energy
- 5,661.8 kWh
- Target annual energy
- 5,661.8 kWh
- Base annual electricity cost
- 1,075.74 USD
- Target annual electricity cost
- 1,075.74 USD
- Annual cost difference
- 0 USD
Inputs
- Design flow
- 125 gpm
- Total dynamic head
- 100 ft
- Pump efficiency
- 66 %
- Motor efficiency
- 88 %
- Base frequency
- 60 Hz
- Target frequency
- 60 Hz
- Run time
- 9 h/day
- Operating days per year
- 155 days
- Energy tariff
- 0.19 USD/kWh
- Liquid specific gravity
- 1
- Drive efficiency
- 100 %
Worked calculation
Calculate useful water power
Pwater = ρgQH
125 gpm at 100 ft and specific gravity 1 requires 3.16 hp of hydraulic work.
Allow for pump, motor and drive losses
Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.
The shaft needs 4.79 hp. Motor input is 5.44 hp and electrical input before the drive is 4.06 kW.
Scale to the target frequency
r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.
60 Hz ÷ 60 Hz gives a speed ratio of 1. Target input is 4.06 kW.
Estimate annual energy and cost
Annual kWh = input kW × annual hours. Cost = kWh × tariff.
9 h/day × 155 days gives 1,395 h per year. The two speeds use 5,661.8 kWh and 5,661.8 kWh.
What this example shows
Seasonal kWh depends on measured input power and run hours. Adjust the tariff to your actual energy charge and add any demand charges separately.
Frequently asked questions
Does a 5 HP irrigation pump always draw 5 × 746 watts?
The motor rating describes shaft output at rated load. Duty point and motor efficiency determine the actual electrical input.
Where do I enter the irrigation season in this estimate?
Enter operating days per year and average hours per operating day. Entering 155 days gives the seasonal runtime used here.