30 Hz Pump Affinity Estimate with a Static-Head Limit
Check the theoretical half-speed duty of a 100 gpm, 160 ft pump when the lift alone may be 55 ft.
Inputs
Results
Updates as you editAffinity estimates assume comparable pump efficiency and the same run hours.
- Flow ∝ speed
- Head ∝ speed²
- Power ∝ speed³
The marker shows target-speed power as a share of base power.
- Hydraulic water power
- 4.05 hp
- Brake power at pump shaft
- 5.78 hp
- Motor electrical input equivalent
- 6.35 hp
- Wire-to-water efficiency
- 61.2 %
- Target-speed flow
- 50 gpm
- Target-speed head
- 40 ft
- Target-speed electrical input
- 0.62 kW
- Base annual energy
- 9,868.2 kWh
- Target annual energy
- 1,233.5 kWh
- Base annual electricity cost
- 1,381.54 USD
- Target annual electricity cost
- 172.69 USD
- Annual cost difference
- 1,208.85 USD
Inputs
- Design flow
- 100 gpm
- Total dynamic head
- 160 ft
- Pump efficiency
- 70 %
- Motor efficiency
- 91 %
- Base frequency
- 60 Hz
- Target frequency
- 30 Hz
- Run time
- 10 h/day
- Operating days per year
- 200 days
- Energy tariff
- 0.14 USD/kWh
- Liquid specific gravity
- 1
- Drive efficiency
- 96 %
Worked calculation
Calculate useful water power
Pwater = ρgQH
100 gpm at 160 ft and specific gravity 1 requires 4.05 hp of hydraulic work.
Allow for pump, motor and drive losses
Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.
The shaft needs 5.78 hp. Motor input is 6.35 hp and electrical input before the drive is 4.93 kW.
Scale to the target frequency
r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.
30 Hz ÷ 60 Hz gives a speed ratio of 0.5. Target input is 0.62 kW.
Estimate annual energy and cost
Annual kWh = input kW × annual hours. Cost = kWh × tariff.
10 h/day × 200 days gives 2,000 h per year. The two speeds use 9,868.2 kWh and 1,233.5 kWh.
What this example shows
The target-speed head at the corresponding point is 40 ft. Compare the reduced-speed shutoff head with the 55 ft lift and intersect the full curves to establish actual delivery.
Frequently asked questions
Will half speed always deliver half the water against a 55 ft lift?
The similar point has half the flow and one-quarter of the head. A fixed system lift can shift the actual intersection or eliminate delivery.
Which curve value tells me if the pump can start moving water at 30 Hz?
Compare reduced-speed shutoff head against the static lift and any required residual pressure.