Well and transfer pumps

1.5 HP Submersible Well Pump at 200 ft TDH

Work through a 12 gpm well with 30 ft of drawdown and a 31 psi outlet, then check a candidate 1.5 HP pump near 200 ft TDH.

Inputs

Total dynamic head202.54 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head202.54 ft

The candidate curve has sufficient head at the target flow.

Pump and system curves
Pump and system curvesThe two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.048121620071.5143214.5286Flow (gpm)Head (ft)Target duty · 202.54 ftIntersection · 204.85 ft
  • System curve
  • Entered pump curve

The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.

Static elevation lift
125 ft
Outlet pressure head
71.63 ft
Darcy straight-pipe loss
5.38 ft
Hazen–Williams straight-pipe loss
5.06 ft
Fitting loss
0.54 ft
Pipe velocity
2.57 ft/s
Pipe inside diameter
1.38 in
Candidate head at target
221.84 ft
Estimated intersection flow
14.43 gpm
Estimated intersection head
204.85 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    85 ft + 30 ft = 115 ft below the wellhead. The outlet then gives 125 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    31 psig gives 71.63 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 12 gpm the selected method adds 5.38 ft and fittings add 0.54 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    125 ft + 71.63 ft + 5.38 ft + 0.54 ft = 202.54 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 221.84 ft at 12 gpm, a head difference of 19.3 ft.

What this example shows

The requested duty is just over 200 ft of head. Compare 12 gpm at that head against the specific 1.5 HP model’s published curve and check shaft load with the horsepower calculator.

Frequently asked questions

Can every 1.5 HP submersible pump deliver 12 gpm at 200 ft TDH?

Stage count and impeller design set the curve. Check both flow and head on the published chart for the exact pump model.

Where do the 30 ft of drawdown go in this well calculation?

They add to the 85 ft static water depth, giving a pumping water level 115 ft below the wellhead.