Farmhouse Well Pump Head at 40 PSI
Combine a 70 ft pumping water depth, a 20 ft rise and 40 psi at the farmhouse in a 12 gpm pump duty.
Inputs
Results
Updates as you editThe candidate curve has sufficient head at the target flow.
- System curve
- Entered pump curve
The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.
- Static elevation lift
- 90 ft
- Outlet pressure head
- 92.43 ft
- Darcy straight-pipe loss
- 15.93 ft
- Hazen–Williams straight-pipe loss
- 15.39 ft
- Fitting loss
- 1.6 ft
- Pipe velocity
- 4.45 ft/s
- Pipe inside diameter
- 1.049 in
- Candidate head at target
- 225.79 ft
- Estimated intersection flow
- 14.8 gpm
- Estimated intersection head
- 207.97 ft
Inputs
- Target flow
- 12 gpm
- Static water depth
- 50 ft
- Pumping drawdown
- 20 ft
- Outlet above wellhead
- 20 ft
- Required outlet pressure
- 40 psig
- Pipe material
- PVC Schedule 40
- Nominal pipe size
- 1 in nominal
- Developed pipe length
- 200 ft
- Use friction method
- Darcy–Weisbach
- Water temperature
- 68 °F
- 90° elbows
- 3
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Hazen–Williams C override
- 0
- Darcy roughness override
- 0 in
- Shutoff head at zero flow
- 260 ft
- Rated curve flow
- 22 gpm
- Head at rated curve flow
- 145 ft
Worked calculation
Find the pumping water level
Pumping depth = static depth + drawdown
50 ft + 20 ft = 70 ft below the wellhead. The outlet then gives 90 ft of static lift.
Convert delivery pressure to head
Hₚ = p / (ρg)
40 psig gives 92.43 ft of pressure head at the entered water temperature.
Add pipe and fitting losses
H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).
At 12 gpm the selected method adds 15.93 ft and fittings add 1.6 ft.
Build the duty point
TDH = static lift + pressure head + straight-pipe loss + fittings
90 ft + 92.43 ft + 15.93 ft + 1.6 ft = 199.96 ft.
Compare with the candidate pump
H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²
The candidate develops 225.79 ft at 12 gpm, a head difference of 25.83 ft.
What this example shows
The pressure requirement adds roughly 92 ft of water head. Run a second duty at the pressure switch cut-out using the flow expected near that point.
Frequently asked questions
Does a 40 psi reading at the well cap represent pressure inside the farmhouse?
Use the required pressure at the delivery point. The elevation and pipe losses between the cap and house belong in the head budget.
Why check 60 psi as a second farmhouse duty?
A 40/60 switch asks the pump to reach the higher cut-out pressure during refill. Consult the pump curve for the corresponding lower flow.