Well and transfer pumps

Farmhouse Well Pump Head at 40 PSI

Combine a 70 ft pumping water depth, a 20 ft rise and 40 psi at the farmhouse in a 12 gpm pump duty.

Inputs

Total dynamic head199.96 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head199.96 ft

The candidate curve has sufficient head at the target flow.

Pump and system curves
Pump and system curvesThe two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.04.48.813.217.622071.5143214.5286Flow (gpm)Head (ft)Target duty · 199.96 ftIntersection · 207.97 ft
  • System curve
  • Entered pump curve

The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.

Static elevation lift
90 ft
Outlet pressure head
92.43 ft
Darcy straight-pipe loss
15.93 ft
Hazen–Williams straight-pipe loss
15.39 ft
Fitting loss
1.6 ft
Pipe velocity
4.45 ft/s
Pipe inside diameter
1.049 in
Candidate head at target
225.79 ft
Estimated intersection flow
14.8 gpm
Estimated intersection head
207.97 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    50 ft + 20 ft = 70 ft below the wellhead. The outlet then gives 90 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    40 psig gives 92.43 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 12 gpm the selected method adds 15.93 ft and fittings add 1.6 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    90 ft + 92.43 ft + 15.93 ft + 1.6 ft = 199.96 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 225.79 ft at 12 gpm, a head difference of 25.83 ft.

What this example shows

The pressure requirement adds roughly 92 ft of water head. Run a second duty at the pressure switch cut-out using the flow expected near that point.

Frequently asked questions

Does a 40 psi reading at the well cap represent pressure inside the farmhouse?

Use the required pressure at the delivery point. The elevation and pipe losses between the cap and house belong in the head budget.

Why check 60 psi as a second farmhouse duty?

A 40/60 switch asks the pump to reach the higher cut-out pressure during refill. Consult the pump curve for the corresponding lower flow.