Pump Head for an Aging Galvanized Well Line
Estimate a retrofit duty for an older 1-inch galvanized well line at 9 gpm with a lower Hazen–Williams C of 90.
Inputs
Results
Updates as you editThe candidate curve has sufficient head at the target flow.
- System curve
- Entered pump curve
The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.
- Static elevation lift
- 37 ft
- Outlet pressure head
- 80.88 ft
- Darcy straight-pipe loss
- 19.48 ft
- Hazen–Williams straight-pipe loss
- 32.57 ft
- Fitting loss
- 1.21 ft
- Pipe velocity
- 3.34 ft/s
- Pipe inside diameter
- 1.049 in
- Candidate head at target
- 182.5 ft
- Estimated intersection flow
- 11.13 gpm
- Estimated intersection head
- 167.97 ft
Inputs
- Target flow
- 9 gpm
- Static water depth
- 24 ft
- Pumping drawdown
- 8 ft
- Outlet above wellhead
- 5 ft
- Required outlet pressure
- 35 psig
- Pipe material
- Galvanized steel Sch 40
- Nominal pipe size
- 1 in nominal
- Developed pipe length
- 280 ft
- Use friction method
- Hazen–Williams
- Water temperature
- 68 °F
- 90° elbows
- 5
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Hazen–Williams C override
- 90
- Darcy roughness override
- 0 in
- Shutoff head at zero flow
- 210 ft
- Rated curve flow
- 18 gpm
- Head at rated curve flow
- 100 ft
Worked calculation
Find the pumping water level
Pumping depth = static depth + drawdown
24 ft + 8 ft = 32 ft below the wellhead. The outlet then gives 37 ft of static lift.
Convert delivery pressure to head
Hₚ = p / (ρg)
35 psig gives 80.88 ft of pressure head at the entered water temperature.
Add pipe and fitting losses
H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).
At 9 gpm the selected method adds 32.57 ft and fittings add 1.21 ft.
Build the duty point
TDH = static lift + pressure head + straight-pipe loss + fittings
37 ft + 80.88 ft + 32.57 ft + 1.21 ft = 151.66 ft.
Compare with the candidate pump
H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²
The candidate develops 182.5 ft at 9 gpm, a head difference of 30.84 ft.
What this example shows
A measured pressure drop between two gauges can narrow the range of plausible pipe losses. Use the roughness and bore overrides to bracket the effect of deposits.
Frequently asked questions
When should I lower the C factor for a galvanized retrofit?
Use a measured loss or a field-supported lower C when corrosion and deposits make the new-pipe lookup optimistic.
What if scale has reduced the physical opening in the old well line?
Enter the reduced inside diameter as well as a plausible roughness. The bore has a strong effect on velocity and friction.