Well and transfer pumps

Pump Head for an Aging Galvanized Well Line

Estimate a retrofit duty for an older 1-inch galvanized well line at 9 gpm with a lower Hazen–Williams C of 90.

Inputs

Total dynamic head151.66 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head151.66 ft

The candidate curve has sufficient head at the target flow.

Pump and system curves
Pump and system curvesThe two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.03.67.210.814.418066.08132.16198.24264.33Flow (gpm)Head (ft)Target duty · 151.66 ftIntersection · 167.97 ft
  • System curve
  • Entered pump curve

The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.

Static elevation lift
37 ft
Outlet pressure head
80.88 ft
Darcy straight-pipe loss
19.48 ft
Hazen–Williams straight-pipe loss
32.57 ft
Fitting loss
1.21 ft
Pipe velocity
3.34 ft/s
Pipe inside diameter
1.049 in
Candidate head at target
182.5 ft
Estimated intersection flow
11.13 gpm
Estimated intersection head
167.97 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    24 ft + 8 ft = 32 ft below the wellhead. The outlet then gives 37 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    35 psig gives 80.88 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 9 gpm the selected method adds 32.57 ft and fittings add 1.21 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    37 ft + 80.88 ft + 32.57 ft + 1.21 ft = 151.66 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 182.5 ft at 9 gpm, a head difference of 30.84 ft.

What this example shows

A measured pressure drop between two gauges can narrow the range of plausible pipe losses. Use the roughness and bore overrides to bracket the effect of deposits.

Frequently asked questions

When should I lower the C factor for a galvanized retrofit?

Use a measured loss or a field-supported lower C when corrosion and deposits make the new-pipe lookup optimistic.

What if scale has reduced the physical opening in the old well line?

Enter the reduced inside diameter as well as a plausible roughness. The bore has a strong effect on velocity and friction.