Well and transfer pumps

Dry-Season Well Drawdown and Pump Sizing

Model a 15 gpm deep well with 45 ft of extra drawdown and 50 psi at an outlet 6 ft above the wellhead.

Inputs

Total dynamic head285.62 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head285.62 ft

The candidate curve has sufficient head at the target flow.

Pump and system curves
Pump and system curvesThe two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.05101520250105.87211.75317.62423.5Flow (gpm)Head (ft)Target duty · 285.62 ftIntersection · 297 ft
  • System curve
  • Entered pump curve

The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.

Static elevation lift
151 ft
Outlet pressure head
115.54 ft
Darcy straight-pipe loss
17.95 ft
Hazen–Williams straight-pipe loss
17.34 ft
Fitting loss
1.14 ft
Pipe velocity
3.75 ft/s
Pipe inside diameter
1.278 in
Candidate head at target
332.8 ft
Estimated intersection flow
19.48 gpm
Estimated intersection head
297 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    100 ft + 45 ft = 145 ft below the wellhead. The outlet then gives 151 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    50 psig gives 115.54 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 15 gpm the selected method adds 17.95 ft and fittings add 1.14 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    151 ft + 115.54 ft + 17.95 ft + 1.14 ft = 285.62 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 332.8 ft at 15 gpm, a head difference of 47.18 ft.

What this example shows

Dry-season depth pushes the curve upward at the same flow. Use a pumping test from the low-water season to check available yield and pump submergence.

Frequently asked questions

Should I use the bottom of the well for the dry-season head figure?

Use the stabilized pumping water level. The drop-pipe length still contributes pipe friction from the pump up to the outlet.

What changes if dry-season drawdown rises as flow increases?

Build several duty points with the measured depth at each flow. The displayed system curve uses a fixed drawdown for its sweep.