Booster Pump Head for a Gravity-Fed Water Line
Calculate the head needed for 14 gpm at 25 psi when the delivery point is 22 ft below a supply reservoir.
Inputs
Results
Updates as you editThe candidate curve has sufficient head at the target flow.
- System curve
- Entered pump curve
The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.
- Static elevation lift
- -22 ft
- Outlet pressure head
- 57.77 ft
- Darcy straight-pipe loss
- 4.46 ft
- Hazen–Williams straight-pipe loss
- 4.19 ft
- Fitting loss
- 0.46 ft
- Pipe velocity
- 2.21 ft/s
- Pipe inside diameter
- 1.61 in
- Candidate head at target
- 66.38 ft
- Estimated intersection flow
- 20.92 gpm
- Estimated intersection head
- 45.88 ft
Inputs
- Target flow
- 14 gpm
- Static water depth
- 0 ft
- Pumping drawdown
- 0 ft
- Outlet above wellhead
- -22 ft
- Required outlet pressure
- 25 psig
- Pipe material
- PVC Schedule 40
- Nominal pipe size
- 1½ in nominal
- Developed pipe length
- 330 ft
- Use friction method
- Darcy–Weisbach
- Water temperature
- 68 °F
- 90° elbows
- 4
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Hazen–Williams C override
- 0
- Darcy roughness override
- 0 in
- Shutoff head at zero flow
- 83 ft
- Rated curve flow
- 25 gpm
- Head at rated curve flow
- 30 ft
Worked calculation
Find the pumping water level
Pumping depth = static depth + drawdown
0 ft + 0 ft = 0 ft below the wellhead. The outlet then gives -22 ft of static lift.
Convert delivery pressure to head
Hₚ = p / (ρg)
25 psig gives 57.77 ft of pressure head at the entered water temperature.
Add pipe and fitting losses
H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).
At 14 gpm the selected method adds 4.46 ft and fittings add 0.46 ft.
Build the duty point
TDH = static lift + pressure head + straight-pipe loss + fittings
-22 ft + 57.77 ft + 4.46 ft + 0.46 ft = 40.69 ft.
Compare with the candidate pump
H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²
The candidate develops 66.38 ft at 14 gpm, a head difference of 25.68 ft.
What this example shows
Gravity supplies 22 ft of head before pipe resistance. Enter a lower outlet pressure to see when the system head crosses zero at the chosen flow.
Frequently asked questions
Why is the booster outlet elevation negative in this example?
The reservoir water surface is the reference. A delivery point below that surface supplies gravity head, which subtracts from the pump requirement.
How can a gravity line have positive TDH without lifting water?
The target outlet pressure and flow-dependent losses can together exceed the available elevation drop.