Well and transfer pumps

Booster Pump Head for a Gravity-Fed Water Line

Calculate the head needed for 14 gpm at 25 psi when the delivery point is 22 ft below a supply reservoir.

Inputs

Total dynamic head40.69 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head40.69 ft

The candidate curve has sufficient head at the target flow.

Pump and system curves
Pump and system curvesThe two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.0510152025022.8345.6568.4891.3Flow (gpm)Head (ft)Target duty · 40.69 ftIntersection · 45.88 ft
  • System curve
  • Entered pump curve

The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.

Static elevation lift
-22 ft
Outlet pressure head
57.77 ft
Darcy straight-pipe loss
4.46 ft
Hazen–Williams straight-pipe loss
4.19 ft
Fitting loss
0.46 ft
Pipe velocity
2.21 ft/s
Pipe inside diameter
1.61 in
Candidate head at target
66.38 ft
Estimated intersection flow
20.92 gpm
Estimated intersection head
45.88 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    0 ft + 0 ft = 0 ft below the wellhead. The outlet then gives -22 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    25 psig gives 57.77 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 14 gpm the selected method adds 4.46 ft and fittings add 0.46 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    -22 ft + 57.77 ft + 4.46 ft + 0.46 ft = 40.69 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 66.38 ft at 14 gpm, a head difference of 25.68 ft.

What this example shows

Gravity supplies 22 ft of head before pipe resistance. Enter a lower outlet pressure to see when the system head crosses zero at the chosen flow.

Frequently asked questions

Why is the booster outlet elevation negative in this example?

The reservoir water surface is the reference. A delivery point below that surface supplies gravity head, which subtracts from the pump requirement.

How can a gravity line have positive TDH without lifting water?

The target outlet pressure and flow-dependent losses can together exceed the available elevation drop.