Well and transfer pumps

Uphill Storage Tank Pump Head with 600 ft of HDPE

Size a pasture transfer line at 22 gpm using 600 ft of 1½-inch DR 11 HDPE and an open tank 90 ft uphill.

Inputs

Total dynamic head112.28 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head112.28 ft

The candidate curve has sufficient head at the target flow.

Pump and system curves
Pump and system curvesThe two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.07.214.421.628.836045.3890.75136.13181.5Flow (gpm)Head (ft)Target duty · 112.28 ftIntersection · 118.77 ft
  • System curve
  • Entered pump curve

The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.

Static elevation lift
90 ft
Outlet pressure head
0 ft
Darcy straight-pipe loss
21.35 ft
Hazen–Williams straight-pipe loss
20.88 ft
Fitting loss
0.92 ft
Pipe velocity
3.72 ft/s
Pipe inside diameter
1.555 in
Candidate head at target
130.27 ft
Estimated intersection flow
25.38 gpm
Estimated intersection head
118.77 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    0 ft + 0 ft = 0 ft below the wellhead. The outlet then gives 90 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    0 psig gives 0 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 22 gpm the selected method adds 21.35 ft and fittings add 0.92 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    90 ft + 0 ft + 21.35 ft + 0.92 ft = 112.28 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 130.27 ft at 22 gpm, a head difference of 17.99 ft.

What this example shows

The 90 ft elevation difference stays fixed as the transfer flow changes. Alter flow to see the friction part of the duty rise and read the curve intersection.

Frequently asked questions

Which elevation should I enter for an open uphill storage tank?

Use the controlling discharge elevation, such as the top inlet or the high water surface when the outlet is submerged.

Does changing HDPE DR change the same nominal pipe size hydraulically?

Yes. The wall thickness changes the inside bore. Enter the specific product’s measured or published inside diameter.