Uphill Storage Tank Pump Head with 600 ft of HDPE
Size a pasture transfer line at 22 gpm using 600 ft of 1½-inch DR 11 HDPE and an open tank 90 ft uphill.
Inputs
Results
Updates as you editThe candidate curve has sufficient head at the target flow.
- System curve
- Entered pump curve
The two-point pump curve is an interpolation. The system curve holds the entered pumping water level fixed.
- Static elevation lift
- 90 ft
- Outlet pressure head
- 0 ft
- Darcy straight-pipe loss
- 21.35 ft
- Hazen–Williams straight-pipe loss
- 20.88 ft
- Fitting loss
- 0.92 ft
- Pipe velocity
- 3.72 ft/s
- Pipe inside diameter
- 1.555 in
- Candidate head at target
- 130.27 ft
- Estimated intersection flow
- 25.38 gpm
- Estimated intersection head
- 118.77 ft
Inputs
- Target flow
- 22 gpm
- Static water depth
- 0 ft
- Pumping drawdown
- 0 ft
- Outlet above wellhead
- 90 ft
- Required outlet pressure
- 0 psig
- Pipe material
- HDPE IPS DR 11
- Nominal pipe size
- 1½ in nominal
- Developed pipe length
- 600 ft
- Use friction method
- Darcy–Weisbach
- Water temperature
- 68 °F
- 90° elbows
- 2
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Hazen–Williams C override
- 0
- Darcy roughness override
- 0 in
- Shutoff head at zero flow
- 165 ft
- Rated curve flow
- 36 gpm
- Head at rated curve flow
- 72 ft
Worked calculation
Find the pumping water level
Pumping depth = static depth + drawdown
0 ft + 0 ft = 0 ft below the wellhead. The outlet then gives 90 ft of static lift.
Convert delivery pressure to head
Hₚ = p / (ρg)
0 psig gives 0 ft of pressure head at the entered water temperature.
Add pipe and fitting losses
H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).
At 22 gpm the selected method adds 21.35 ft and fittings add 0.92 ft.
Build the duty point
TDH = static lift + pressure head + straight-pipe loss + fittings
90 ft + 0 ft + 21.35 ft + 0.92 ft = 112.28 ft.
Compare with the candidate pump
H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²
The candidate develops 130.27 ft at 22 gpm, a head difference of 17.99 ft.
What this example shows
The 90 ft elevation difference stays fixed as the transfer flow changes. Alter flow to see the friction part of the duty rise and read the curve intersection.
Frequently asked questions
Which elevation should I enter for an open uphill storage tank?
Use the controlling discharge elevation, such as the top inlet or the high water surface when the outlet is submerged.
Does changing HDPE DR change the same nominal pipe size hydraulically?
Yes. The wall thickness changes the inside bore. Enter the specific product’s measured or published inside diameter.